Amateur Radio Practices
Interference to consumer electronics; grounding; DSP
Which of the following might be useful in reducing RF interference to audio frequency devices?
A bypass capacitor takes in extra noise or radio frequency interference (RFI) in the system and filters it out.
A diode lets current flow in one direction. If a diode is forward-biased, it's letting current flow, and if it's reverse-biased, it's blocking it. Neither of these things would help remove RF interference.
There is, apparently, such a thing as a bypass inductor, but it's not common, and it's hard to find any information about it, and it doesn't seem like it would help filter out RF interference.
For more info see Wikipedia: Bypass (Decoupling) capacitor, Radio frequency interference (RFI)
Last edited by glitteribbon. Register to edit
Tags: none
Which of the following could be a cause of interference covering a wide range of frequencies?
One source of interference could come from arcing at a poor electrical connection. Arcing because of poor wiring or a shorted component will cause fluctuations in the voltage passing that point.
Out of the handbook "Arcing- Any spark or sustained arc creates radio noise over a wide range of frequencies and will interfere with both amateur and consumer reception. [G4C02]"
For more info see Wikipedia: Electrical Arcing
Last edited by chicagoway. Register to edit
Tags: none
What sound is heard from an audio device or telephone if there is interference from a nearby single sideband phone transmitter?
Hearing distorted speech on an audio device or telephone may occur if there is interference from a nearby single-sideband phone transmitter. Phones and stereos can sometimes pick up extra RF signals from nearby sources, just like your station receiver does, but the speech will be distorted.
Last edited by kd7bbc. Register to edit
Tags: none
What is the effect on an audio device when there is interference from a nearby CW transmitter?
Telephones or audio devices can sometimes pick up interference RF signals from nearby transmission sources. If the interference is coming from a nearby CW transmitter, an on-and-off humming or clicking will be heard, which is a distorted version of the CW transmission. If the nearby interfering station was transmitting in SSB voice, distorted speech would be heard instead.
CW stands for "continuous wave" transmissions. Originally communication was accomplished with a "straight key" and the operator, using "Morse Code" simply used the key to interrupt a continuous transmission into "dits" and "dahs", which explains why there will be clicking from CW interference.
Last edited by kyferez. Register to edit
Tags: none
What might be the problem if you receive an RF burn when touching your equipment while transmitting on an HF band, assuming the equipment is connected to a ground rod?
If you receive an RF burn when touching your equipment while transmitting on an HF band even though the equipment is connected to a ground rod, it may be because the ground wire has high impedance on that frequency. Remember impedance is a resistance to the flow of electrons, if the ground wire has high impedance, then it might have enough "apparent" resistance to make flowing through your equipment or your body a more efficient (lower resistance) path to ground.
Silly hint: if you get a burn on your hand, it will impede your ability to use the hand.
Last edited by debshinder432. Register to edit
Tags: none
What effect can be caused by a resonant ground connection?
A resonant ground connection can cause high RF voltages on the enclosures of station equipment.
Even though the equipment is grounded, if the ground wire is long enough it can actually resonate on the frequency you are using to transmit. When this happens, instead of acting to remove extra current, the ground wire gains high impedance, and so blocks the flow of electrons to the ground state. This means your enclosure, equipment or even body can become a more efficient path to ground, and conduct high RF voltages.
Hint: [R]esonant ground = high [R]F
Last edited by mike881. Register to edit
Tags: none
Why should soldered joints not be used with the wires that connect the base of a tower to a system of ground rods?
Solder melts at such a low temperature compared to the incredible heat produced by a lightning strike that soldered joints would melt instantly and be destroyed. In situations where lightning strikes are more likely (like an antenna tower) ground clamps are the way to go.
Last edited by kd7bbc. Register to edit
Tags: none
Which of the following would reduce RF interference caused by common-mode current on an audio cable?
RF interference caused by common-mode current on an audio cable can be reduced by placing a ferrite bead around the cable. The ferrite bead, which can also be called a ferrite choke among other names, is used as a device to reduce noise in audio cables because of the high dissipation qualities of the ferrite material.
For more info see Wikipedia: Common-mode interference, Ferrite bead
Last edited by kd7bbc. Register to edit
Tags: none
How can a ground loop be avoided?
A ground loop in your circuits can be avoided by connecting all of the ground conductors to a single point. A ground loop, or extra current path, is usually caused by components that are not designed or wired correctly. Loops can cause noise and interference. Keeping all wiring in direct paths, and especially connecting all of your ground conductors to a single point, help to keep loops from being formed.
For more info see Wikipedia: Ground loops
Last edited by kd7bbc. Register to edit
Tags: none
What could be a symptom of a ground loop somewhere in your station?
If stations that are receiving your communications report back to you that they are hearing a "hum" on your station's transmitted signal, you may have a ground loop somewhere in your station. This unwanted noise caused by picking up distortion from magnetic field voltages or from improper connections can be remedied by connecting all of your ground conductors to a single point.
For more info see Wikipedia: ground loop
Last edited by ironcal67. Register to edit
Tags: none
What technique helps to minimize RF "hot spots" in an amateur station?
Just as you would tie all of your radio grounds together to prevent things such as ground loops, you want to bond all your radios together as well.
Not bonding radios together can result in potential differences being present between them. Potential differences often result in high voltages being present on certain pieces of the radios, such as, a metal microphone piece, or even the radio itself.
Last edited by oatkinson. Register to edit
Tags: none
Which of the following is an advantage of a receiver DSP IF filter as compared to an analog filter?
An advantage of a receiver digital signal processor (DSP) IF (intermediate frequency) filter compared to an analog filter, is that a wide range of filter bandwidths and shapes can be created. The software and processing abilities of the DSP unit make it a very flexible instrument for either filtering or other modifications, signal modulation or other adjustments to the received signal.
For more info see Wikipedia: Digital signal processor, Digital Signal Processing
Last edited by mk2019. Register to edit
Tags: none
Why must the metal enclosure of every item of station equipment be grounded?
It is good practice when setting up your station to make sure that you have grounded any equipment with a metal chassis. Excess voltage can be caught in the metal housing if there is a short within the equipment or wiring. Proper grounding ensures that you will not have a SHOCKING experience when you touch your equipment due to hazardous voltages on the chassis.
Hint: A "metal enclosure" houses the "chassis".
Last edited by mike881. Register to edit
Tags: none